The AA Series of high-voltage regulated DC-DC converters addresses the needs of the miniature PCB-mount regulated high voltage power supply user. Designed and built utilizing state-of- the-art power-conversion topology, these units feature surface- mount technology and encapsulation techniques that provide high reliability and performance. Typical applications for the AA Series include the following: bias supplies, detectors, piezos, amplifiers, and photomultiplier tubes (PMT).
  • 22% smaller than standard A Series
  • 8 models from 0 to 62V through 0 to 6kV
  • 4, 20 or 30 watts of output power
  • Maximum Iout capability down to 0 Volts
  • Wide input voltage range • >1,250,000 hour MTBF @65°C
  • Indefinite output short-circuit protection
  • Output current & voltage monitors
  • Fixed-frequency, low-stored-energy design
  • UL, cUL, CE, IEC-60950-1, and Demko Recognized   
 
Parameter Conditions models Units
inPUt   12V 24V  
Voltage Range Full Power + 11 to 16 + 23 to 30 VDC
Voltage Range Derated Power Range + 9 to 32 + 9 to 32 VDC
Current Standby / Disable < 30 < 30 mA
Current No Load, Max Eout < 100 < 90 mA
Current Max Load, Max Eout ~ 400 ~ 1350 mA
AC Ripple Current Nominal Input, Full Load < 80 < 80 mA p-p
oUtPUt   1/16aa 1/8aa 1/4aa 1/2aa 1aa 2aa 4aa 6aa  
Voltage Range Nominal Input 0 to 62 0 to 125 0 to 250 0 to 500 0 to 1,000 0 to 2,000 0 to 4,000 0 to 6,000 VDC
Nominal Input Voltage / Model 12 24 24 12 24 24 12 24 24 12 24 24 12 24 24 12 24 24 12 24 24 12 24 24 VDC
Power Nominal Input, Max Eout 4 20 30 4 20 30 4 20 30 4 20 30 4 20 30 4 20 30 4 20 30 4 20 30 Watts
Current Iout Entire Output Voltage Range 64 320 480 32 160 240 16 80 120 8 40 60 4 20 30 2 10 15 1 5 7.5 0.67 3.3 5 mA
Current Scale Factor Full Load 42.67 969.7 960 11.64 237 258 3.27 70.48 72.7 .79 17.78 17.65 .37 4.60 4.62 .192 1.52 1.52 .090 .752 .76 .066 .490 .50 mA/V
Voltage Monitor Scaling 10:1 ± 2% into 10MΩ 100:1 ± 2% into 10MΩ -
Ripple Full Load, Max Eout 0.03 0.06 0.15 0.03 0.038 0.038 0.023 0.04 0.05 0.01 0.01 0.011 0.026 0.048 0.073 0.01 0.011 0.046 0.042 0.050 0.070 0.035 0.024 0.046 %V p-p
Dynamic Load Regulation ½ to Full Load, Max Eout per .1mA <.12 <.12 <.12 <.12 <.12 <.12 <.20 <.20 <.20 <.50 <.50 <.50 <1.0 <1.0 <1.0 <2.0 <2.0 <2.0 <4.0 <4.0 <4.0 <6.0 <6.0 <6.0 V pk
Line Regulation Nom. Input, Max Eout, Full Power < 0.01 % VDC
Static Load Regulation No Load to Full Load, Max Eout < 0.01% VDC
Stability 30 Min. warmup, per 8 hr/ per day < 0.01% / < 0.02% VDC
ProGramminG & Controls all tYPes  
Input Impedance Nominal Input + Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref MΩ
Adjust Resistance Typical Potentiometer Values 10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)
Adjust Logic 0 to +5 for +Out, +5 to 0 for - Out +4.64 VDC for +Output or +0.36 for -Output = Nominal Eout -
Output Voltage & Impedance T=+25°C + 5.00VDC ± 2%, Zout = 464Ω ± 1% -
Enable/Disable 0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable) VDC
enVironmental all tYPes  
Operating Full Load, Max Eout, Case Temp. -40 to +65 °C
Coefficient Over the Specified Temperature ±50 PPM/°C
Thermal Shock Mil-Std 810, Method 503-4, Proc. II -40 to +65 °C
Storage Non-Operating, Case Temp. -55 to +105 °C
Humidity All Conditions, Standard Package 0 to 95% non-condensing -
Altitude Standard Package, All Conditions Sea Level through Vacuum (Vacuum may require -P1 or -S1 options, contact factory for details) -
Shock Mil-Std-810, Method 516.5, Proc. IV 20 G’s
Vibration Mil-Std-810, Method 514.5, Fig.514.5C-3 10 G’s